PRP Kits: What's Inside, How to Choose & Where to Source

Educational content only. Not medical advice. Consult a licensed practitioner for clinical decisions.

CE-marked medical device · ISO 13485 quality management system · Sterile, single-use, individually packaged · 24-month shelf life · LOT and EXP on every unit · Manufacturer-direct

What Is a PRP Kit?

A PRP kit is a sterile, single-use package containing the collection tubes and the accessories needed to draw, transfer and deliver autologous platelet-rich plasma in one procedure, matched to the tube specification and supplied together as a single unit. Where a PRP tube is one component in that workflow, a kit is the complete consumable set for the procedure — the tube plus the butterfly needle, needle holder, syringes, transfer needle, connector and delivery needles it is used with.

The kit is the consumable half of the workflow. The centrifuge the tubes are run in is equipment: purchased, installed and maintained separately, and outside the scope of a consumable pack. VivaPRP kits are supplied in ACD-A anticoagulation with a density-gradient separation gel, and in an ACD-A + gel + biotin configuration for hair-focused workflows.

This guide covers what a kit contains, why a clinic buys one instead of individual components, how to choose between the configurations and pack sizes we supply, how to check the kit's 15 ml tube against your rotor, and the wholesale, sample and OEM terms. Tube chemistry and clinical selection are treated in depth in the PRP tubes guide; this page stays on the kit — its contents, its economics and its purchasing logic.

What a PRP Kit Includes

Kit contents are fixed per configuration rather than assembled from a catalogue. The bill of materials for the ACD Gel System kit, per set:

Component Per set What it is for
PRP collection tube, 15 ml 2 ACD-A anticoagulant with density-gradient cell selector gel; each tube individually sterile-packaged
Needle holder 1 Holds the collection needle through venepuncture
Butterfly needle 1 Venepuncture
Syringe, 5 ml 1 Draw and bulk transfer
Syringe, 2 ml 1 Delivery
30G needle 2 Fine delivery
Needle connector 1 Joins syringe to transfer line
Transfer needle 1 Moves separated plasma between containers

Two 15 ml tubes and seven accessory line items per set. The set is complete for one procedure: no additional consumable has to be sourced to run the workflow it is configured for, and nothing in it is reusable.

The tube inside the kit

The kit tube is a 15 ml format: 16 mm outer diameter, 120 mm in length, ACD-A anticoagulant with an integrated density-gradient gel barrier. It is ethylene-oxide sterilised and individually wrapped, in the same specification we supply across the PRP tube range, and it is the component that determines separation quality — everything else in the kit exists to move blood and plasma between containers without contaminating either.

What the other kit line publishes

The VivaPRP Kit collection system is published at configuration level rather than item level: it is supplied as an ACD Gel Kit or an ACD+Gel+B Kit, with collection tubes, anticoagulant solution and separation gel included. Its itemised accessory list is confirmed per configuration on request, and it should be asked for in writing before a first order rather than assumed to mirror the set above. That is the rule for any kit, ours included: the bill of materials, not the product name, is the specification. A listing that reports a "20-piece kit" without separating tubes from swabs cannot be compared with one that does.

Why Buy a Kit: Four Problems It Solves

A kit is not cheaper than buying tubes in bulk and it is not a higher grade of tube. It solves four problems that sit around the tube rather than inside it, and it is worth buying when at least two of them are costing you something.

1. Component matching

A PRP workflow runs through six or seven connections — needle to holder, holder to tube, tube to syringe, syringe to transfer needle, transfer needle to delivery needle — and each one is a gauge and a fitting that either mates or does not. Buying them separately means specifying each, and a mismatch shows up at the chair, not at the order. A kit is a set already checked for compatibility with the tube it ships with.

2. One line item instead of six

Individual sourcing means six SKUs to forecast, reorder and reconcile, each with its own stock-out risk. A kit collapses that into one SKU at a fixed per-procedure cost, which is the difference between knowing your consumable cost per procedure and reconstructing it. For a clinic running several practitioners across several sites, it also removes the variation between what one room has on the shelf and what another does.

3. Sterility at assembly, not at the chair

Components bought separately arrive sterile in their own packaging and are opened in the treatment room, one at a time. A kit arrives as a set that was assembled and packaged under controlled conditions, so the number of sterile fields opened during a procedure falls, and so does the handling between them.

4. Predictable cost per procedure

The kit price is the consumable cost of one procedure, already known, with no assembly of per-item prices to build a margin model on. That is a purchasing convenience with a financial consequence: procedure pricing can be set against a figure that does not drift when one component's pack size changes.

When tubes alone is the better buy

The honest counterpoint belongs in the same section as the advantages. A kit is priced per procedure set and tubes are priced per tube, so the two must be put on a per-procedure basis before either looks expensive or cheap.

Route What one procedure consumes Listed price Consumable cost per procedure
Kit set 2 × 15 ml ACD-A + gel tubes, plus the seven-item accessory set $75 per set $75
Tubes in bulk, own accessories 2 × 15 ml ACD-A + gel tubes from a 50-tube box $199 per 50-tube box About $8 of tube cost, plus accessories you already stock

The gap is the accessory set and the packaging around it, not the tubes. That is what should decide the purchase. A clinic already stocking butterfly needles, 5 ml and 2 ml syringes, 30G delivery needles, connectors and transfer equipment is buying inventory it already holds, and tubes in bulk will be materially cheaper per procedure. A clinic that is not — or that does not want six consumable SKUs across several gauges, each resupplied separately — is buying exactly what the four points above describe.

The per-procedure cost model, including what consumable cost does to procedure margin, is worked through in PRP kit cost analysis. The component-level version of this comparison is in what a PRP kit contains.

How to Choose a PRP Kit: Four Decisions in Order

Most kit comparisons start with price or pack size, which are the two decisions that can be made correctly last. The sequence below produces a specification you can compare against another supplier's line by line.

  1. Fix the configuration. ACD-A + gel is the default; ACD+Gel+B where the workflow is hair-focused. This is the only decision that cannot be reversed without also changing a validated protocol.
  2. Confirm the tube fits your rotor. Every kit in the range carries a 15 ml tube measuring 16 × 120 mm, which needs a deeper rotor seat than a 16 × 100 mm tube. A tube that does not seat makes every later decision irrelevant, so check it before pack size.
  3. Choose the pack size, against reorder frequency and the shelf life that will remain at the point of last use — not against the discount on the largest pack.
  4. Confirm the bill of materials in writing, including gauges. A kit that ships a delivery needle your practitioners will not use is a kit you are paying twice for.

Which configuration suits which application is covered by use case in kits for hair restoration and kits for facial aesthetics, and the clinical parameter framework behind step one in how to choose a PRP kit.

Kit Configurations and Current Range

Two kit lines are supplied, carrying two anticoagulant configurations. Pack sizes differ between the lines, so the line is chosen before the pack size.

Kit line Configuration Pack sizes Listed price
ACD Gel System ACD-A + density-gradient cell selector gel 1 / 3 / 5 sets $75 / $179 / $239
VivaPRP Kit collection system ACD Gel Kit; or ACD+Gel+B Kit (biotin) One configuration per variant $79 / $89

Listed prices are current store prices with no promotional code applied; where a promotion runs, the checkout price is lower. Kit prices are per set, and a set is one procedure's consumables — not one tube.

The biotin variant differs at the additive level, not the anticoagulant level. It uses the same ACD-A anticoagulation and the same gel separation, with biotin (vitamin B7) released into the plasma fraction during centrifugation, and is intended for hair-focused workflows. Choosing between the two is a workflow question rather than a quality question; the anticoagulant systems themselves are compared in PRP tube anticoagulants.

Rotor Fit: The Kit's 15 ml Tube

Every format in the range shares a 16 mm outer diameter, so diameter tells you nothing about whether a tube will seat. Seat depth decides, and 120 mm is the constraint for the kit tube.

Requirement What to check
Position bore Accepts a 16 mm outer-diameter tube without an adapter
Seat depth Accommodates 120 mm tube length, not 100 mm
Position count Enough positions for the 2 tubes in a set, plus balancing positions
Force per rotor Maximum RCF published for that specific rotor, not for the machine as a whole

A rotor rated for 16 × 100 mm formats takes the kit tube only if its seat is deep enough. A narrow-bore 5 ml rotor will not take a 16 mm tube without an adapter, and an adapter changes the sample radius. The tube and rotor compatibility reference maps each configuration to the rotors it seats in and gives the published maximum force per rotor; where a protocol is written in one unit and your machine in another, the rpm to RCF converter handles the conversion. Machines we supply are in the centrifuge range.

From Draw to Separated Plasma

The kit fixes the consumables; the sequence is the same as any ACD-A + gel workflow.

  1. Draw into the collection tube. The tube is evacuated, so the draw volume is set by the vacuum inside it. Fill to the marked line — an underfilled tube spins differently from a full one, and the blood-to-anticoagulant ratio shifts with it.
  2. Mix gently. Invert the tube 8–10 times so the anticoagulant reaches the whole sample. Vigorous shaking causes haemolysis, which shows up as red-tinged plasma.
  3. Balance the rotor and spin. The recommended setting is 1,500 rpm for 8 minutes, at which point the gel migrates to form the separation barrier. rpm describes the machine, not the force the sample receives, so confirm the equivalent × g against your own rotor before running a new tube format.
  4. Separate and aspirate. Aspirate the plasma layer above the gel without disturbing the barrier. The stated yield for the 15 ml kit tube is approximately 4–6 ml of PRP per tube.

Two tubes per set therefore return roughly 8–12 ml of PRP. Whether that covers a session depends on the area treated and the delivery technique, not on the kit. Where a protocol calls for activation, calcium chloride or thrombin is added after separation and outside the tube — that reagent is not part of the kit. Protocol design, single spin versus double spin and what changes between them, is in single spin vs double spin PRP.

Sterility, Certification and Documentation

VivaPRP kits are CE-marked medical devices, supplied sterile, single-use and individually packaged, and manufactured under an ISO 13485 quality management system. Those are the four claims that should appear on any kit listing you compare against — and the four that should be documented rather than asserted.

Ask for the following before a first order:

  • CE documentation for the kit's device class, showing the notified body.
  • ISO 13485 certificate with a registration number you can check.
  • The sterilisation method and its validation for the configuration supplied. Cycles differ by product family and by production run, so the authoritative figure is the one on the lot documentation that ships with the order, not a general statement on a page.
  • LOT, production date and EXP on every unit, so a batch can be recorded against the procedure.
  • Instructions for use in the language of your market.

How to check those documents against public registers, and what a CE mark does and does not cover, are set out in the CE marking guide and in FDA-cleared versus CE-certified PRP systems.

Storage, Handling and Shelf Life

  • Shelf life: 24 months from manufacture.
  • Storage: 4–25 °C, away from direct light, in the original packaging.
  • Do not freeze — freezing compromises the anticoagulant formulation and tube integrity.
  • Inspect before use: confirm the sterile packaging is intact, the gel is undisturbed and the EXP date has not passed.
  • Single use — one draw per tube, disposed of under your facility's biohazard procedure.

Remaining shelf life at the point of delivery is the figure that matters on a bulk order, because a multi-session course can run several months. Ask for it in writing and check it against the interval to your last planned session, rather than against the labelled life at manufacture. Production date bears on performance as well: an evacuated tube's draw volume depends on the vacuum, and both the vacuum and the gel are validated only for the labelled life. The dimensions and material questions behind tube choice are in PRP tube sizes and materials.

Sourcing: Wholesale, Samples, Shipping and OEM

Kits are supplied direct from the manufacturer, in single sets, multi-set packs and wholesale quantities, with pricing, documentation and logistics handled through one contact.

Option Detail
Single set Lists at the per-set price and is the practical way to run one procedure on your own machine before committing to volume
Multi-set packs 3-set and 5-set packs on the ACD Gel System line, at a lower per-set price than the single set
Wholesale Minimum quantities are set per configuration rather than as one site-wide number, and are confirmed at quotation
OEM / private label Your brand and label on the same kit, with label printing and packaging setup ahead of the production run
Trial A single set run through your own centrifuge answers the rotor-fit and yield question more reliably than any specification sheet, including this one

Shipping is free worldwide to clinics, distributors and healthcare professionals in 40+ countries. Transit is approximately 10–20 business days after dispatch depending on destination, and customs processing can extend it. Lead time on branded and custom production is confirmed at quotation.

Commercial terms are on the wholesale page; the branding process and typical timeline are in OEM and private label; wider ordering, packaging and delivery questions are answered in the PRP tubes and kits FAQ. Current stock is in the PRP kit collection.

Frequently Asked Questions

1. What is included in a VivaPRP PRP kit?

In the ACD Gel System kit, per set: two 15 ml ACD-A + gel collection tubes, one needle holder, one butterfly needle, one 5 ml syringe, one 2 ml syringe, two 30G needles, one needle connector and one transfer needle. The VivaPRP Kit collection system is supplied as an ACD Gel Kit or an ACD+Gel+B Kit, with its itemised accessory list confirmed per configuration on request.

2. What is the difference between a PRP kit and PRP tubes?

A tube is one component. A kit is the tube plus the matched accessory set for one procedure — needle holder, butterfly needle, syringes, connector, transfer needle and delivery needles — supplied sterile and packaged together.

3. Does the kit contain an activation agent?

No. Where a protocol calls for activation, calcium chloride or thrombin is added after separation, outside the tube, and is sourced and documented separately. It is not part of the kit or of its CE marking.

4. Which tube volume is in the kit?

A 15 ml tube, measuring 16 × 120 mm. All formats in the range share a 16 mm outer diameter, so the length — and therefore the rotor seat depth — is what determines fit.

5. Can I run the kit's tubes in my own centrifuge?

Yes, if the rotor accepts a 16 mm tube of 120 mm length. A narrow-bore 5 ml rotor needs an adapter, and an adapter changes the sample radius. The compatibility reference maps each format to the rotors it seats in.

6. What centrifugation setting is recommended for the kit?

1,500 rpm for 8 minutes, at which point the gel forms the separation barrier. That figure describes the machine; the force delivered depends on the rotor radius, so convert it against your own rotor with the rpm to RCF converter before running a new tube format.

7. How much PRP does one kit set produce?

The stated yield is approximately 4–6 ml per 15 ml tube, so a two-tube set returns roughly 8–12 ml. How many treatment areas that covers depends on the protocol and the delivery technique, not on the kit.

8. Is the kit CE-marked and sterile?

Yes — CE-marked as a medical device, supplied sterile, single-use and individually packaged, and manufactured under an ISO 13485 quality management system. Confirm the sterilisation method on the lot documentation for the configuration you receive.

9. How long do kits last, and how should they be stored?

24 months from manufacture, stored at 4–25 °C away from direct light in the original packaging. Do not freeze. Inspect the sterile packaging and the EXP date before use.

10. Is a kit cheaper than buying tubes and accessories separately?

Not always, and the answer depends on what you already stock. Per procedure, a kit set is $75; the two tubes in it account for about $8 at 50-tube bulk pricing. The difference is the matched accessory set and its packaging. If you already stock those accessories, tubes in bulk cost less per procedure; if you do not, the kit removes six or more separate SKUs from your ordering.

11. Can I order kits in bulk or under my own brand?

Yes — wholesale quantities and OEM / private label are both available. Minimums are set per configuration and confirmed at quotation; see wholesale terms and OEM and private label.

Where to Go Next

If the kit decision is made, the PRP kit collection lists every configuration and pack size with current pricing. If it is not — if you already stock the accessory set and only need tubes — the PRP tubes collection sells them by the box. For the tube itself, chemistry, gel technology and selection by application, the PRP tubes guide is the companion reference. For the device side, the rotor compatibility reference answers the fit question. For fibrin rather than plasma, see the PRF tubes guide.

Related Reading

Shop PRP kits → Browse the collection · Wholesale & bulk · Contact our team

Disclaimer: This page provides consumable and specification information for healthcare professionals and procurement teams. It does not constitute medical advice and does not describe a clinical protocol. Centrifugation parameters, treatment parameters and device use must follow your own validated protocol, the device instructions for use and local regulatory requirements.